Properties
| Breite in mm: | 200 mm |
|---|---|
| Stärke in mm: | 10 mm |
Shaft bearings 10 x 200 mm
Description
Profiled elastomeric bearing.
Applications: Footfall sound insulation and structure-borne sound insulation between components and prefrabricated construction.
- Strength 10 N/mm²
- Expansion 350%
- Schore-hardness 70°C
Every desired length can be cutted.
The shaft bearing has three tear seam every 5 cm.
You can modify the profiled elastomeric bearing to requested width of 5, 10 and 15 cm.
Properties
| Breite in mm: | 200 mm |
|---|---|
| Stärke in mm: | 10 mm |
Ähnliche Artikel
The impact sound bearing is a PUR-bound rubber granulate forSupporting stairs and ceilings. Technical specifications: Volume weight 820 kg / m³Basis weight 820 g / m² / mmTear strength according to DIN 53571 1.2 N / mm²Elongation at break according to DIN 53571 90%Temperature resistance -40 ° C - 90 ° CFire behavior according to DIN 4102 class B2Recommended load 0.1 - 0.4 N / mm²Feather area approx. 0.7 - 1.5 mm
Customers also viewed
The impact sound bearing is a PUR-bound rubber granulate forSupporting stairs and ceilings. Technical specifications: Volume weight 820 kg / m³Basis weight 820 g / m² / mmTear strength according to DIN 53571 1.2 N / mm²Elongation at break according to DIN 53571 90%Temperature resistance -40 ° C - 90 ° CFire behavior according to DIN 4102 class B2Recommended load 0.1 - 0.4 N / mm²Feather area approx. 0.7 - 1.5 mm
Sylomer impact sound bearing SR 450 Area of application Pressure load Deformation Form factor dependent, the specified values apply to form factor q = 3 Static area of application(static loads) up to 0,45 N/mm² approx. 10 % Dynamic area of application(static and dynamic loads) up to 0,70 N/mm² approx. 20% Peak loads(rare, short-term loads) up to 5,0 N/mm² approx. 60%
Einsatzbereich Druckbelastung Verformung formfaktorabhängig, die angegebenen Werte gelten für Formfaktor 3 Statischer Einsatzbereich(statische Lasten) bis 0,35 N/mm² ca. 10 % Dynamischer Einsatzbereich(statische und dynamische Lasten) bis 0,50 N/mm² ca. 17 % Lastspitzen(seltene, kurzzeitige Lasten) bis 4,2 N/mm2 ca. 50 %
Sylomer impact sound bearing SR 450 Area of application Pressure load Deformation Form factor dependent, the specified values apply to form factor q = 3 Static area of application(static loads) up to 0,45 N/mm² approx. 10 % Dynamic area of application(static and dynamic loads) up to 0,70 N/mm² approx. 20% Peak loads(rare, short-term loads) up to 5,0 N/mm² approx. 60%
The P-Cable Basic HRD annular seal is available in various designs.The following product identification is used: SG x (number of holes) / y-z (area in which the hole can be adjusted)
Einsatzbereich Druckbelastung Verformung formfaktorabhängig, die angegebenen Werte gelten für Formfaktor 3 Statischer Einsatzbereich(statische Lasten) bis 0,75 N/mm² ca. 11 % Dynamischer Einsatzbereich(statische und dynamische Lasten) bis 1,20 N/mm² ca. 17 % Lastspitzen(seltene, kurzzeitige Lasten) bis 6,0 N/mm2 ca. 40 %
Sylomer sound bearing bearing type SR 28 Area of application Pressure load Deformation Form factor dependent, the specified values apply to form factor q = 3 Static area of application(static loads) up to 0,028 N/mm² approx. 7 % Dynamic area of application(static and dynamic loads) up to 0,037 N/mm² approx. 20 % Peak loads(rare, short-term loads) up to 1,0 N/mm² approx. 75 %
Einsatzbereich Druckbelastung Verformung formfaktorabhängig, die angegebenen Werte gelten für Formfaktor 3 Statischer Einsatzbereich(statische Lasten) bis 1,50 N/mm² ca. 11 % Dynamischer Einsatzbereich(statische und dynamische Lasten) bis 2,00 N/mm² ca. 16 % Lastspitzen(seltene, kurzzeitige Lasten) bis 6,80 N/mm2 ca. 30 %
Sylomer impact sound bearing type SR 55 Area of application Pressure load Deformation Form factor dependent, the specified values apply to form factor q = 3 Static area of application(static loads) up to 0,055 N/mm² approx. 7 % Dynamic area of application(static and dynamic loads) up to 0,076 N/mm² approx. 20% Peak loads(rare, short-term loads) up to 2,0 N/mm² approx. 75%
Sylomer impact sound bearing type SR 11 - YELLOW Area of application Pressure load Deformation Form factor dependent, the specified values apply to form factor q = 3 Static area of application(static loads) up to 0,011 N/mm² approx. 7% Dynamic area of application(static and dynamic loads) up to 0,016 N/mm² approx. 20% Peak loads(rare, short-term loads) up to 0,5 N/mm² approx. 80%