Skip to main content Skip to search Skip to main navigation
Filter products
Variants

With the help of our variant list you can find your article faster and easier.

Product Nr.
Product
Innen ø in mm
Länge in mm
Price
Action
61LXDL100500
KG - Bodendurchlässe
100 mm
500 mm
61LXDL125500
KG - Bodendurchlässe
125 mm
500 mm
61LXDL150500
KG - Bodendurchlässe
150 mm
500 mm
61LXDL200500
KG - Bodendurchlässe
200 mm
500 mm
61LXDL250500
KG - Bodendurchlässe
250 mm
500 mm
Skip product gallery

Zubehör

KG-Deckel
KG cover for Pipe bushing and floor outlets
KG-Muffenring
For floor outlets
Skip product gallery

Customers also viewed

KG - Bodendurchlässe
MPA tested! KG pipe length 0.5 mwith water stop and one-sided sleeve without cover
Kunststoff-Futterrohr WELLO mit Quellband
WELLO, the lining tube made of PE with an all-round swelling coating. The tube is smooth inside. The undulating outside clings to the concrete. Two swelling tapes applied around the center also prevent water from entering the structure Wello casing, double security through corrugation and swelling tape, sealing by means of an annular seal. Tested up to 30m water column.
KG - Bodendurchlässe
MPA tested! KG pipe length 0.5 mwith water stop and one-sided sleeve without cover
KG - Bodendurchlässe
MPA tested! KG pipe length 0.5 mwith water stop and one-sided sleeve without cover
KG-Deckel
KG cover for Pipe bushing and floor outlets
Kunststoff-Futterrohr WELLO mit Quellband
WELLO, the lining tube made of PE with an all-round swelling coating. The tube is smooth inside. The undulating outside clings to the concrete. Two swelling tapes applied around the center also prevent water from entering the structure Wello casing, double security through corrugation and swelling tape, sealing by means of an annular seal. Tested up to 30m water column.
Mauerkragen aus TPE - Themoplastischem Elastomer
MPA certificated! Masonry collars from TPE-Themoplastic Elastomer Application area:The sealing collar is used whenever a water-tight lead-through of pipe lines through foundation slabs, walls, and masonry is required. The sealing collar, which has passed the pressure test at 5 bar, prevents moisture from getting into the building along the outer pipe walls. Tested for impermeability up to 50 m water column. Properties:The sealing collar is supplied in pre-assembled condition with 2 stainless steel straps. The circular, 4 cm wide collar, which is equipped with additional waterstops, prevents liquids from getting into the building. Small waterstops inside the collar ensure water-tightness up to a water column of 50 m after tightening of the stainless steel fastening straps.Assembly clean pipe surface if necessary slide on the sealing collar and fix it in the centre of the concrete/wall tighten the fastening straps
Spacer Speedies ceiling SH
Application: For concreting storey ceilings or concrete slabs as spacers for the lower reinforcement. Furthermore, the Speedies surface spacers can also be used very well in the precast concrete plant thanks to the pointed feet. With this design, the pointed feet achieve an optimal concrete flow and thereby reduce visibility in the concrete surface. Your advantage: Material polypropylene-PP Pressure-resistant / very high stability Ergonomic Transport-optimized (Euro pallet) Consumption approx. 1-1.5 pieces / m² patent pending MPA approved
Spacer Speedies ceiling SH
Application: For concreting storey ceilings or concrete slabs as spacers for the lower reinforcement. Furthermore, the Speedies surface spacers can also be used very well in the precast concrete plant thanks to the pointed feet. With this design, the pointed feet achieve an optimal concrete flow and thereby reduce visibility in the concrete surface. Your advantage: Material polypropylene-PP Pressure-resistant / very high stability Ergonomic Transport-optimized (Euro pallet) Consumption approx. 1-1.5 pieces / m² patent pending MPA approved
Faserzement-Futterrohr
The fiber cement wall sleeves are available for immediate delivery from DN 80 to DN 600. The tube is smooth on the inside and roughened on the outside. Because the undulating outside connects with the concrete no water circulation occurs.