Sylomer SR 1200/25 weinrot
Sylomer Trittschall-Lager Typ SR 1200 Einsatzbereich Druckbelastung Verformung Formfaktorabhängig, die angegebenen Werte gelten für Formfaktor q = 3 Statischer Einsatzbereich(statische Lasten) bis 1,2 N/mm² ca. 11% Dynamischer Einsatzbereich(statische und dynamische Lasten) bis 1,8 N/mm² ca. 17% Lastspitzen(seltene, kurzzeitige Lasten) bis 6,0 N/mm² ca. 35%            
Sylomer-Polyurethanlager SR110
Sylomer sound bearing bearing type SR110 Area of application Pressure load Deformation Form factor dependent, the specified values apply to form factor q = 3 Static area of application(static loads) up to 0,110 N/mm² approx. 10 % Dynamic area of application(static and dynamic loads) up to 0,160 N/mm² approx. 20% Peak loads(rare, short-term loads) up to 3,0 N/mm² approx. 70%
Sylomer-Polyurethanlager SR 28
Sylomer sound bearing bearing type SR 28 Area of application Pressure load Deformation Form factor dependent, the specified values apply to form factor q = 3 Static area of application(static loads) up to 0,028 N/mm² approx. 7 % Dynamic area of application(static and dynamic loads) up to 0,037 N/mm² approx. 20 % Peak loads(rare, short-term loads) up to 1,0 N/mm² approx. 75 %
Sylomer-Polyurethanlager SR 450
Sylomer impact sound bearing SR 450 Area of application Pressure load Deformation Form factor dependent, the specified values apply to form factor q = 3 Static area of application(static loads) up to 0,45 N/mm² approx. 10 % Dynamic area of application(static and dynamic loads) up to 0,70 N/mm² approx. 20% Peak loads(rare, short-term loads) up to 5,0 N/mm² approx. 60%          
Sylomer SR 1200/12 weinrot
Sylomer Trittschall-Lager Typ SR 1200 Einsatzbereich Druckbelastung Verformung Formfaktorabhängig, die angegebenen Werte gelten für Formfaktor q = 3 Statischer Einsatzbereich(statische Lasten) bis 1,2 N/mm² ca. 11% Dynamischer Einsatzbereich(statische und dynamische Lasten) bis 1,8 N/mm² ca. 17% Lastspitzen(seltene, kurzzeitige Lasten) bis 6,0 N/mm² ca. 35%            
Sylomer-Polyurethanlager SR 55
Sylomer impact sound bearing type SR 55 Area of application Pressure load Deformation Form factor dependent, the specified values apply to form factor q = 3 Static area of application(static loads) up to 0,055 N/mm² approx. 7 % Dynamic area of application(static and dynamic loads) up to 0,076 N/mm² approx. 20% Peak loads(rare, short-term loads) up to 2,0 N/mm² approx. 75%
Trapezoidal strips PVC
Trapezoidal strip made of PVC. Other dimensions on request.
Sylomer-Polyurethanlager SR 28
Sylomer sound bearing bearing type SR 28 Area of application Pressure load Deformation Form factor dependent, the specified values apply to form factor q = 3 Static area of application(static loads) up to 0,028 N/mm² approx. 7 % Dynamic area of application(static and dynamic loads) up to 0,037 N/mm² approx. 20 % Peak loads(rare, short-term loads) up to 1,0 N/mm² approx. 75 %
Sylomer-Polyurethanlager SR 450
Sylomer impact sound bearing SR 450 Area of application Pressure load Deformation Form factor dependent, the specified values apply to form factor q = 3 Static area of application(static loads) up to 0,45 N/mm² approx. 10 % Dynamic area of application(static and dynamic loads) up to 0,70 N/mm² approx. 20% Peak loads(rare, short-term loads) up to 5,0 N/mm² approx. 60%          
SAM spacers; Exposed concrete already attached
Spacer system SAM for exposed concrete. (the concrete wall remains visible, there is no further cladding) In combination with 27 mm standard formwork panels, can be used quickly and easily. Packing units: up to a wall thickness of 30 cm 100 pieces / boxFrom a wall thickness of 31 cm 50 pieces / box Spacer for quick and economical shuttering of concrete and retaining walls. All special lengths (in cm increments) from 6 - 300 cm possible.